skyraySkyrayCS-188High frequency infrared carbon sulfur analyzer
Product Description, Technical Parameters, and Configuration
Instrument Introduction
High frequency infrared carbon sulfur analyzer is a high-tech product that integrates optical, mechanical, electrical, computer, and analytical technologies. It has the characteristics of wide measurement range and accurate and reliable analysis results. Due to the use of computer technology, the intelligence of the instrument, the display of images and text on the screen, and the collection and processing of data are all excellent, making it an ideal analytical equipment for determining carbon and sulfur elements in many industries.
CS-188The high-frequency infrared carbon sulfur analyzer is an analytical instrument carefully crafted by Tianrui Instrument Company based on years of technical accumulation for users. It has excellent performance, complete functions, wide linear range, low detection limit, fast analysis speed, stable performance, small size, and simple operation. It can accurately determine the mass fraction of carbon and sulfur in steel, iron, alloy, non-ferrous metals, cement, ore, glass and other materials.
performance advantage
1High frequency combustion method:
The combustion method of using front oxygen and rear oxygen control (both our company and the American Lico company use this combustion method) ensures that the sample is fully burned and the measurement results of carbon and sulfur are more accurate.
2Carbon monoxide compensation:
A carbon monoxide infrared detection system was added to the system design, which not only measures the carbon dioxide generated in each sample, but also measures the amount of carbon monoxide generated in this analysis. When calculating the total carbon content, these two parts are added together to obtain the total carbon content in the sample.
3Temperature compensation
In order to solve the problem of infrared signal stability being affected by environmental temperature interference, the system introduces a temperature compensation design. The system's analysis results from morning till night are not significantly affected by changes in environmental temperature factors, making the instrument suitable for both comfortable laboratory environments and relatively harsh environments.
4Pressure compensation
Add an atmospheric pressure sensor in the system design to monitor real-time pressure changes in the environment and incorporate this parameter into the system compensation algorithm.
5Traffic compensation
The design adopts a digital mass flowmeter, which can extract instantaneous flow signals (which cannot be achieved by a float flowmeter), and the instantaneous flow rate is also taken into account in the software algorithm.
6Peak width compensation
Effectively improved the reproducibility index of the system. This greatly improves the overall linearity of the system and expands its range.
7Capture background interference
Make the carbon analysis results unaffected by changes in carbon dioxide concentration in the surrounding environment. Improved the reproducibility and repeatability of each analysis result.
8Program controlled high voltage system overload
High voltage overload short circuit automatic protection and automatic cut-off (one minute). The high voltage application time can be controlled, greatly improving the lifespan of the power transistor.
9Automatic fault detection and backup function:
Automatically detect each control valve,Mainly analyze signals and system analysis parameters (temperature),pressure,Check if the current is normal, provide timely alarms in case of faults, and dynamically monitor the current signal changes of the system during the analysis process.
10Software Design
Function *: In terms of database management, it has achieved automatic storage of data, possesses functions *, multiple filtering database retrieval engines, synchronized display, storage, and amplification of work curves, as well as multi-level comparison and analysis results of multiple curvesEXELThere are dozens of functions such as report output.
Humanized design: The interface design is simple and elegant, making human-computer interaction more convenient.
technical indicators
Carbon element:
CS-188:0.0005% - 5%Small indication value0.00001%
CS-188:RSD≤0.5% (relative standard deviation)
Analysis time less than50S
reach, achieve, attainISO9556Standard requirements, higher thanJJG395-97requirement
Sulfur element:
CS-188:0.0005% - 3.5%Small indication value0.00001%
CS-188:RSD≤1.8% (relative standard deviation)
Analysis time less than50S
Accuracy: achievedISO4935Standard requirements, higher thanJJG395-97requirement
Instrument sensitivity:0.1ppm
High frequency furnace power:2.5KW
High frequency furnace frequency:20MHz
Standard Configuration
1High frequency combustion instrument host1Taiwan
2, detector1Taiwan
3Attachment box (including spare pipelines, tool kits, spare parts, etc.)
4, electronic balance1Taiwan
application field
CS-188The high-frequency infrared carbon sulfur analyzer adopts a high-frequency induction furnace combined with an infrared carbon sulfur analysis system, which can quickly and accurately determine the carbon and sulfur elements in various materials such as steel, iron, alloys, non-ferrous metals, rare earth metals, ores, cement, coke, coal, slag, glass, ceramics, refractory materials, catalysts, etc.